PRODUCTS
PAMAX
Active Power Filter
Effective harmonic solution with the advanced active harmonic compensation technology
Powerful controller based on dual-DSP architecture allowing for ultra-fast and precise compensation
Utilize double interleaved inverter topology to reduced ripple current and lower heat loss.
Broad spectrum of cancellation, from 2nd to 50th harmonics
Increase system stability, reduce of equipment malfunctions.
Reduce power loss which cause by harmonic current and reactive power
Solve phase unbalancing problem with load balancing function
Available both industrial type (floor standing cabinet) for durable work and module type for easy installation and compact area.
PQSVG
Static Var Generator
The latest technology in the reactive power compensation devices comes with the active harmonic compensation function
Improving power factor both Lagging PF. และ Leading PF.
Harmonic compensation range 30% of rate capacity, available for harmonic order 2nd to 13th
Increase system stability, reduce of equipment malfunctions.
Reduce power loss which cause by reactive power and harmonic current
Solve phase unbalancing problem with load balancing function
Available both industrial type (floor standing cabinet) for durable work and module type for easy installation and compact area.
PQASVG
Advance High Voltage Static Var Generator with Harmonic Filtering Function
The latest technology in the reactive power compensation devices at 3.3 - 35 kV comes with the active harmonic compensation function
Improving power factor both Lagging PF. และ Leading PF.
Harmonic compensation range 30% of rate capacity, available for harmonic order 2nd to 25th
Increase system stability, reduce of equipment malfunctions.
Reduce power loss which cause by reactive power and harmonic current
Solve phase unbalancing problem with Load Balancing Function
Available both indoor type (cabinet) and outdoor type (container) depend on installation area
PFMAX
Real-Time Power Factor Correction System
Reactive power compensation device designed based on detuned filter in combination with high speed thyristor controlled Switch
Improve power factor
Fast compensates reactive power to its full capacity without voltage and current surges
Switching time less than 20ms, Suitable for loads with rapidly changing reactive power requirements.
No resonance problems
No over voltage and under voltage from overcompensation and undercompensation of reactive power
reduce power loss which cause by reactive power and harminic current
Low maintenance and long service life
PQDVR
Dynamic Voltage Regulator
Innovative solution to protect against voltage sags, swells, and interruptions that result in damaged sensitive loads
based on Insulated Gate Bipolar Transistors (IGBT) inverter technology and using super capacitors as energy storage components
very fast response time, less than 100us
3 seconds of ride through as standard, other ride through times available upon request
Battery free, no need to replace baterry, low maintenace cost
Long service life
PQPEL
Electronic Load Bank with Energy Feed Back Function
an advanced functional load testing equipment for UPS, generator sets, power supplies
Capability of simulating multiple load types
Resistive loads, inductive loads, capacitive loads and the combinations of those three load types
Unbalanced loads
Three-phase, three-wire and four-wire rectifiers
Step-change load with programmable step speed to ease the response time test of tested samples
Loads with current waveforms customized by user
Energy feedback function feedback the active power into grid
PQ STARTER
High-Torque Motor Starter with Voltage Drop/Sag Elimination
Reduce motor starting current
Reduce voltage sag cause by starting motor
High starting torque
No Harmonics
Improve power factor
reduce power loss
parallel connected, no need to modify the existing starting system
can work together with existing soft-start devices for the more reduced starting current.
Easy to expand, several modules can work in parallel